MIT-BIH ST Change Database record 306, an exercise stress test with reference beat annotations (PhysioNet, ODC-BY). α1 in 120 s windows every 5 s; HRVT1 and HRVT2 from a linear α1~HR fit on the ascending limb only.
DFA-α1 from RR intervals. It estimates the aerobic (α1 = 0.75) and anaerobic (α1 = 0.50) HRV thresholds from a chest-strap or ECG recording, and computes the usual recovery metrics (RMSSD, SDNN, pNN50, Lomb–Scargle LF/HF, Poincaré SD1/SD2). The thing I did not expect: on the same ECG at the same HR of 124 bpm, swapping the R-peak detector moves α1 from 1.00 to 0.61, because a few ms of timing jitter is enough to fake a threshold at exercise HR.
python -m venv .venv && . .venv/bin/activate
pip install -e ".[fit]" # add [validate] to rerun the PhysioNet checks
hrv-threshold alpha1 ride.fit --thresholds --plot alpha1.png --csv alpha1.csv
hrv-threshold metrics morning_h10.txt --json --plot poincare.png
hrv-threshold alpha1 examples/synthetic_ramp.txt --thresholds # bundled synthetic demofrom hrvthreshold import read_rr, alpha1_timeseries, estimate_thresholds, all_metrics
rr = read_rr("ride.fit") # ms
s = alpha1_timeseries(rr) # 120 s / 5 s windows
v = s.valid(max_artifacts=0.05)
th = estimate_thresholds(s.alpha1[v], s.hr[v])
print(th.hrvt1, th.hrvt2, th.r2, th.reliable).fit files are read with fitdecode from the hrv message (up to five RR values per message, 65.535 s means invalid), so turn on HRV/RR logging on the watch and pair a chest strap. CSV/TXT can hold one RR per line (ms or s, auto-detected) or a table with an RR/IBI column, such as Polar Sensor Logger's Phone timestamp;RR-interval [ms].
Tests and the PhysioNet reproduction:
pip install -e ".[dev]" && pytest -q # 41 tests, ~2 s, no network
pip install -e ".[validate]"
python scripts/validate_physionet.py # downloads ~55 MB from PhysioNet
python scripts/make_figures.py # regenerates docs/figuresNo personal health data is in this repository. Put your own recordings in private/, which is git-ignored, as is *.fit.
On synthetic signals (N = 4096, 50 reps) α1 over n = 4–16 gives 0.59 ± 0.02 for white noise (theory 0.50), 1.02 ± 0.02 for pink 1/f and 1.50 ± 0.02 for Brownian. The +0.09 on white noise is the known small-scale bias of DFA-1 (Kantelhardt et al., 2001), and the 0.75/0.50 cut-offs were calibrated with the same estimator in Kubios. Against nolds dfa configured identically, |Δα| < 1e-9 on 15 synthetic configurations and max |Δα| = 8.2e-15 on every valid window of all 38 real PhysioNet records. Raw numbers are in results/.
On real annotated ECG:
| dataset | n | result |
|---|---|---|
| Fantasia, 2 h supine rest | 10 | α1 = 1.05 ± 0.17 (range 0.73–1.27) |
| MIT-BIH ST Change DB, stress tests reaching ≥ 140 bpm | 12 | α1 1.25 at lowest-HR decile, 0.59 at highest; drop > 0.2 in 9/12; median Spearman ρ(α1, HR) = −0.53 |
| same, reliable threshold fits | 7 / 12 | median HRVT1 = 89 % of peak HR, HRVT2 = 95 % |
These are clinical stress-test patients with no gas-exchange reference, so this shows α1 behaves as expected on real data. It says nothing about threshold accuracy against VT1/VT2. Three records reach high HR with no α1 decline (309, 310, 320) and the reliability gate rejects their fits.
On the Wrist PPG During Exercise chest-ECG lead (no beat labels) I compared wfdb XQRS with a band-pass (8–30 Hz) detector with parabolic sub-sample refinement. The band-pass detector gave a valid window on 15/19 records, XQRS on 11/19, and on 3 records their median α1 differs by more than 0.15. The reason is that a timing error
DFA (Peng et al., 1995) integrates the RR series
splits it into
For a self-similar signal
Windows follow Rogers et al. (2021, Front. Physiol.): 120 s, recomputed every 5 s, so a window holds about 120 beats at 60 bpm and about 340 at 170 bpm. A single window has an SD of 0.05–0.09, so thresholds come from an OLS fit
A fit is reliable only if
Recovery metrics follow the Task Force (1996).
- Chest strap or ECG only. Optical PPG has far more timing jitter, which biases α1 low exactly where thresholds live.
- Artifact correction is a simple rule, not the Lipponen & Tarvainen (2019) algorithm behind Kubios "automatic". Expect small differences from Kubios on dirty data.
- Thresholds need an incremental test that crosses 0.75 (and 0.5); otherwise the fit extrapolates and is flagged unreliable.
- The DFA estimator is verified exactly. The threshold mapping is not, because no open dataset here has gas exchange. Simultaneous RR + VO₂ data would be welcome.
- NN intervals only. Arrhythmias, pacing or atrial fibrillation make α1 meaningless.
- Not a medical device.
- Peng C-K, Havlin S, Stanley HE, Goldberger AL. Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series. Chaos 5:82 (1995). doi:10.1063/1.166141
- Kantelhardt JW et al. Detecting long-range correlations with detrended fluctuation analysis. Physica A 295:441 (2001). doi:10.1016/S0378-4371(01)00144-3
- Gronwald T, Rogers B, Hoos O. Fractal correlation properties of heart rate variability: a new biomarker for intensity distribution in endurance exercise and training prescription? Front. Physiol. 11:550572 (2020). doi:10.3389/fphys.2020.550572
- Rogers B, Giles D, Draper N, Hoos O, Gronwald T. A new detection method defining the aerobic threshold for endurance exercise and training prescription based on fractal correlation properties of heart rate variability. Front. Physiol. 11:596567 (2021). doi:10.3389/fphys.2020.596567
- Rogers B, Giles D, Draper N, Mourot L, Gronwald T. Detection of the anaerobic threshold in endurance sports: validation of a new method using correlation properties of heart rate variability. J. Funct. Morphol. Kinesiol. 6:38 (2021). doi:10.3390/jfmk6020038
- Rogers B, Giles D, Draper N, Mourot L, Gronwald T. Influence of artefact correction and recording device type on the practical application of a non-linear heart rate variability biomarker for aerobic threshold determination. Sensors 21:821 (2021). doi:10.3390/s21030821
- Lipponen JA, Tarvainen MP. A robust algorithm for heart rate variability time series artefact correction using novel beat classification. J. Med. Eng. Technol. 43:173 (2019). doi:10.1080/03091902.2019.1640306
- Task Force of the ESC and NASPE. Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation 93:1043 (1996). doi:10.1161/01.CIR.93.5.1043
- Data: Iyengar N et al., Am. J. Physiol. 271:R1078 (1996), doi:10.1152/ajpregu.1996.271.4.R1078 (Fantasia, doi:10.13026/C2RG61). Albrecht P., MIT M.S. thesis (1983) (ST Change DB, doi:10.13026/C2ZW2H). Jarchi D, Casson AJ, Data 2(1):1, doi:10.3390/data2010001 (Wrist PPG, doi:10.13026/C2PQ1X). PhysioNet: Goldberger AL et al., Circulation 101:e215 (2000).
MIT © 2026 Tommaso Maggiolo. See LICENSE and CITATION.cff.