Validated DFA-α1 HRV analysis: aerobic/anaerobic thresholds from RR intervals (FIT, Polar H10) + recovery metrics

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

fractal-threshold

alpha1 during a real exercise stress test

MIT-BIH ST Change Database record 306, an exercise stress test with reference beat annotations (PhysioNet, ODC-BY). α1 in 120 s windows every 5 s; HRVT1 and HRVT2 from a linear α1~HR fit on the ascending limb only.

DFA-α1 from RR intervals. It estimates the aerobic (α1 = 0.75) and anaerobic (α1 = 0.50) HRV thresholds from a chest-strap or ECG recording, and computes the usual recovery metrics (RMSSD, SDNN, pNN50, Lomb–Scargle LF/HF, Poincaré SD1/SD2). The thing I did not expect: on the same ECG at the same HR of 124 bpm, swapping the R-peak detector moves α1 from 1.00 to 0.61, because a few ms of timing jitter is enough to fake a threshold at exercise HR.

Install and use

python -m venv .venv && . .venv/bin/activate
pip install -e ".[fit]"          # add [validate] to rerun the PhysioNet checks

hrv-threshold alpha1 ride.fit --thresholds --plot alpha1.png --csv alpha1.csv
hrv-threshold metrics morning_h10.txt --json --plot poincare.png
hrv-threshold alpha1 examples/synthetic_ramp.txt --thresholds   # bundled synthetic demo
from hrvthreshold import read_rr, alpha1_timeseries, estimate_thresholds, all_metrics
rr = read_rr("ride.fit")                       # ms
s = alpha1_timeseries(rr)                      # 120 s / 5 s windows
v = s.valid(max_artifacts=0.05)
th = estimate_thresholds(s.alpha1[v], s.hr[v])
print(th.hrvt1, th.hrvt2, th.r2, th.reliable)

.fit files are read with fitdecode from the hrv message (up to five RR values per message, 65.535 s means invalid), so turn on HRV/RR logging on the watch and pair a chest strap. CSV/TXT can hold one RR per line (ms or s, auto-detected) or a table with an RR/IBI column, such as Polar Sensor Logger's Phone timestamp;RR-interval [ms].

Tests and the PhysioNet reproduction:

pip install -e ".[dev]" && pytest -q        # 41 tests, ~2 s, no network
pip install -e ".[validate]"
python scripts/validate_physionet.py         # downloads ~55 MB from PhysioNet
python scripts/make_figures.py               # regenerates docs/figures

No personal health data is in this repository. Put your own recordings in private/, which is git-ignored, as is *.fit.

Results

On synthetic signals (N = 4096, 50 reps) α1 over n = 4–16 gives 0.59 ± 0.02 for white noise (theory 0.50), 1.02 ± 0.02 for pink 1/f and 1.50 ± 0.02 for Brownian. The +0.09 on white noise is the known small-scale bias of DFA-1 (Kantelhardt et al., 2001), and the 0.75/0.50 cut-offs were calibrated with the same estimator in Kubios. Against nolds dfa configured identically, |Δα| < 1e-9 on 15 synthetic configurations and max |Δα| = 8.2e-15 on every valid window of all 38 real PhysioNet records. Raw numbers are in results/.

On real annotated ECG:

dataset n result
Fantasia, 2 h supine rest 10 α1 = 1.05 ± 0.17 (range 0.73–1.27)
MIT-BIH ST Change DB, stress tests reaching ≥ 140 bpm 12 α1 1.25 at lowest-HR decile, 0.59 at highest; drop > 0.2 in 9/12; median Spearman ρ(α1, HR) = −0.53
same, reliable threshold fits 7 / 12 median HRVT1 = 89 % of peak HR, HRVT2 = 95 %

These are clinical stress-test patients with no gas-exchange reference, so this shows α1 behaves as expected on real data. It says nothing about threshold accuracy against VT1/VT2. Three records reach high HR with no α1 decline (309, 310, 320) and the reliability gate rejects their fits.

On the Wrist PPG During Exercise chest-ECG lead (no beat labels) I compared wfdb XQRS with a band-pass (8–30 Hz) detector with parabolic sub-sample refinement. The band-pass detector gave a valid window on 15/19 records, XQRS on 11/19, and on 3 records their median α1 differs by more than 0.15. The reason is that a timing error $e_k$ on beat times adds $e_{k+1} - e_k$ to every RR interval, which is anti-correlated noise. At 150 bpm with an RR SD of 4 ms, jitter of σ = 2 ms takes a true α = 1.0 down to α1 ≈ 0.74. At rest (RR SD 40 ms) the same jitter does nothing. One sample at 256 Hz is already 3.9 ms.

How it works

DFA (Peng et al., 1995) integrates the RR series $x_1,\dots,x_N$ into a profile

$$ y(k) = \sum_{i=1}^{k} \left( x_i - \bar x \right), $$

splits it into $N_n = \lfloor N/n \rfloor$ boxes of $n$ beats, removes a least-squares line $\hat y_\nu$ from each box, and takes the RMS of what is left:

$$ F(n) = \sqrt{ \frac{1}{N_n, n} \sum_{\nu=1}^{N_n} \sum_{k \in \nu} \bigl( y(k) - \hat y_\nu(k) \bigr)^2 }. $$

For a self-similar signal $F(n) \propto n^{\alpha}$, and α1 is the OLS slope of $\log F$ against $\log n$ over $n \in {4, \dots, 16}$ beats, the Kubios convention used by the threshold papers. 0.5 is white noise, 1.0 is $1/f$ (healthy resting heart), 1.5 is Brownian; for a $1/f^{\beta}$ spectrum $\alpha = (\beta+1)/2$. With rising intensity, vagal withdrawal breaks the correlations and α1 falls toward 0.5 and below. Rogers et al. (2021) matched α1 = 0.75 to the first ventilatory threshold and α1 = 0.50 to the second.

Windows follow Rogers et al. (2021, Front. Physiol.): 120 s, recomputed every 5 s, so a window holds about 120 beats at 60 bpm and about 340 at 170 bpm. A single window has an SD of 0.05–0.09, so thresholds come from an OLS fit $\alpha_1 = a,\mathrm{HR} + b$ over all windows with $0.25 \le \alpha_1 \le 1.05$:

$$ \mathrm{HRVT1} = \frac{0.75 - b}{a}, \qquad \mathrm{HRVT2} = \frac{0.50 - b}{a} $$

A fit is reliable only if $R^2 \ge 0.5$ and neither threshold is extrapolated outside the observed HR range. Before any of this, beats outside the physiological range or more than 20 % off an 11-beat local median are replaced by cubic spline, and windows with more than 5 % corrected beats are dropped.

Recovery metrics follow the Task Force (1996). $\mathrm{SD1}^2 = \tfrac12 \mathrm{Var}(\Delta x)$, $\mathrm{SD1}^2 + \mathrm{SD2}^2 = 2,\mathrm{Var}(x)$. LF (0.04–0.15 Hz) and HF (0.15–0.40 Hz) come from a Lomb–Scargle periodogram on the unevenly sampled tachogram with no resampling, Parseval-scaled so that $\int P,df$ equals the variance of the detrended series (absolute powers in ms²).

Limitations

  • Chest strap or ECG only. Optical PPG has far more timing jitter, which biases α1 low exactly where thresholds live.
  • Artifact correction is a simple rule, not the Lipponen & Tarvainen (2019) algorithm behind Kubios "automatic". Expect small differences from Kubios on dirty data.
  • Thresholds need an incremental test that crosses 0.75 (and 0.5); otherwise the fit extrapolates and is flagged unreliable.
  • The DFA estimator is verified exactly. The threshold mapping is not, because no open dataset here has gas exchange. Simultaneous RR + VO₂ data would be welcome.
  • NN intervals only. Arrhythmias, pacing or atrial fibrillation make α1 meaningless.
  • Not a medical device.

References

  • Peng C-K, Havlin S, Stanley HE, Goldberger AL. Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series. Chaos 5:82 (1995). doi:10.1063/1.166141
  • Kantelhardt JW et al. Detecting long-range correlations with detrended fluctuation analysis. Physica A 295:441 (2001). doi:10.1016/S0378-4371(01)00144-3
  • Gronwald T, Rogers B, Hoos O. Fractal correlation properties of heart rate variability: a new biomarker for intensity distribution in endurance exercise and training prescription? Front. Physiol. 11:550572 (2020). doi:10.3389/fphys.2020.550572
  • Rogers B, Giles D, Draper N, Hoos O, Gronwald T. A new detection method defining the aerobic threshold for endurance exercise and training prescription based on fractal correlation properties of heart rate variability. Front. Physiol. 11:596567 (2021). doi:10.3389/fphys.2020.596567
  • Rogers B, Giles D, Draper N, Mourot L, Gronwald T. Detection of the anaerobic threshold in endurance sports: validation of a new method using correlation properties of heart rate variability. J. Funct. Morphol. Kinesiol. 6:38 (2021). doi:10.3390/jfmk6020038
  • Rogers B, Giles D, Draper N, Mourot L, Gronwald T. Influence of artefact correction and recording device type on the practical application of a non-linear heart rate variability biomarker for aerobic threshold determination. Sensors 21:821 (2021). doi:10.3390/s21030821
  • Lipponen JA, Tarvainen MP. A robust algorithm for heart rate variability time series artefact correction using novel beat classification. J. Med. Eng. Technol. 43:173 (2019). doi:10.1080/03091902.2019.1640306
  • Task Force of the ESC and NASPE. Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation 93:1043 (1996). doi:10.1161/01.CIR.93.5.1043
  • Data: Iyengar N et al., Am. J. Physiol. 271:R1078 (1996), doi:10.1152/ajpregu.1996.271.4.R1078 (Fantasia, doi:10.13026/C2RG61). Albrecht P., MIT M.S. thesis (1983) (ST Change DB, doi:10.13026/C2ZW2H). Jarchi D, Casson AJ, Data 2(1):1, doi:10.3390/data2010001 (Wrist PPG, doi:10.13026/C2PQ1X). PhysioNet: Goldberger AL et al., Circulation 101:e215 (2000).